Allegion Fire, life safety and accessibility codes 21 Subsequently tested in accordance with NFPA 252/ UL 10B/UL 10C, or NFPA 257, Standard on Fire Test for Window and Glass Block Assemblies, 2017 ed/UL 9 Allowed in fire doors listed up to 3 hours, in maximum size tested Classification of hardware for fire doors (4.6) Builders hardware includes hinges, locks and latches, bolts and closers − Builders hardware is applied to swinging fire doors − Builders hardware shall not be required to be shipped from the factory with the fire doors Fire exit hardware is panic hardware that is labeled for both panic and fire protection Fire door hardware includes surface-mounted strap hinges, surface-applied latches and closing devices − Fire door hardware is applied to swinging and sliding doors − In NFPA 80, hardware for sliding doors shall be fire door hardware − Fire door hardware must be shipped from the factory with the fire door − Typical of tin-clad type doors Clearance at bottom of door (4.8.4) Clearance under the bottom of a fire door: 3/4 inches (19 mm) maximum If bottom of door is more than 38 inches (965 mm) above the floor (for example, a counter shutter or chute door), maximum clearance is 3/8 inch (9.5 mm) or as specified by manufacturer’s label service procedure Note: The 2016 and 2019 editions of NFPA 80 reference products which are listed to address clearances in excess of 3/4 inch (19 mm) Modifications (2022: 5.1.5; Previous: 4.1.3) Job-site prep for surface-applied hardware, function holes for mortise locks and holes for labeled viewers: − Maximum 1 inch (25.4 mm) diameter holes permitted, except cylinder holes may be any size − Note: The 2016 and 2019 editions of NFPA 80 allow job-site preparations of holes larger than 1 inch for surface-mounted hardware if allowed by the door manufacturer’s listings and the hardware manufacturer’s listings. These editions also allow preparations for auxiliary fire pins and raceways for wires to be field drilled in accordance with the door manufacturer’s listings and when permitted by the listing laboratory. − Maximum 3/4 inch (19 mm) undercutting for wood and composite doors allowed − Any preparations other than noted above must be done under label service. − Plant-ons as allowed per the manufacturer’s listings Inspection and testing (5.2) Fire door assemblies must be inspected and tested at least annually; consult standard for details of performance-based option Upon completion of installation and maintenance work, fire door assemblies must be inspected and tested (added in 2013 edition) Written record of inspection signed and kept for AHJ review Inspection performed by qualified individual with knowledge of the type of assembly being inspected Fire door assemblies: visually inspected from both sides to assess overall condition Inspect per the following criteria: − Labels must be visible and legible − No open holes or breaks in surface of door or frame − Glazing, light frames, glazing beads (if present) intact and securely fastened − Door, frame, hinges, hardware and noncombustible threshold (if required) are secure, aligned, in working order, with no damage − No parts missing or broken − Clearances between door edge and frame, measured on the pull side, within allowable limits per NFPA 80 − Self-closing device operational, and active door closes when operated from the full open position − Coordinator (if present) facilitates inactive leaf closing before active leaf − Latching hardware operates and securely latches door in closed position − Auxiliary hardware items that interfere with operation must not be installed on door or frame − No field modifications performed that void the label − Gasketing, where required, is present and intact − Signage on door meets requirements of NFPA 80 Operation of doors ( 2022: 6.1.4; 2019, 2016, 2013: 6.1.3; 2010, 2007: 6.1.4) All swinging fire doors must be closed and latched at the time of fire Door operation classified as: − Self-closing door: Equipped with a closing device, closes each time it is opened (no hold-open) − Automatic-closing door: Closes and latches automatically when released by an automatic fire detector Copyright © 2021 NFPA
Fire Life Safety and Accessibility Codes Book
| Title Name |
Pages |
Delete |
Url |
| Empty |
Ai generated response may be inaccurate.
Search Text Block
Page #page_num
#doc_title
Hi $receivername|$receiveremail,
$sendername|$senderemail wrote these comments for you:
$message
$sendername|$senderemail would like for you to view the following digital edition.
Please click on the page below to be directed to the digital edition:
$thumbnail$pagenum
$link$pagenum
Your form submission was a success.
Downloading PDF
Generating your PDF, please wait...
This process might take longer please wait