28 Allegion Fire, life safety and accessibility codes Decoded: Panic hardware edition to the next, the adopted edition of the NEC should be consulted. The 2021 and 2024 editions of the IBC also require panic hardware on doors serving refrigeration machinery rooms larger than 1,000 square feet (93 m2). The AHJ may request panic hardware in other instances if he or she believes that panic hardware is required for life safety. Of course, panic hardware may also be installed in locations where it is not required by code, for ease of use or the ability to withstand abuse. If a door is not equipped with a latch or lock (push/pull applica- tion), the door is not required to have panic hardware. Keep in mind that when an application requires panic hardware, all of the doors in the means of egress from that room or area will typically require panic hardware, including the exit access, the exit and the exit discharge doors. The exception to this rule is the code requirement for panic hardware on refrigeration machinery rooms and on electrical rooms, which includes only the person- nel doors within 25 feet of the required working space. Other code considerations Where panic hardware is required, the actuating portion of the device (touchpad or crossbar) must measure at least half the width of the door leaf. Current codes require panic hardware to be mounted between 34–48 inches above the floor. Existing panic hardware may have been installed in accordance with previous code requirements. A force of 15 lbs applied to the touchpad or crossbar must release the latch. Some codes and standards require door hardware to operate with 5 lbs of force, which has created a conflict between the codes and standards. No additional locking device (deadlock, chain, padlock and hasp, etc.) may be installed on a door required to have panic hardware, and panic hardware may not be equipped with any device that prevents the release of the latch when the touchpad or crossbar is pressed. There are exceptions in the model codes for some electrified hardware applications. When panic hardware is installed on fire doors, fire exit hardware must be used and the door must be equipped with a label stating “Fire Door to be Equipped with Fire Exit Hardware.” Fire exit hardware is labeled for panic and fire and is not equipped with a mechani- cal “dogging” mechanism. Electric latch retraction may be used to provide dogging for fire exit hardware, as long as the door becomes positively latched during a fire emergency by means of an automatic fail-safe device that is activated by an automatic fire detector. If panic hardware is used on balanced doors (doors where the pivot point is located several inches in from the hinge edge of the door) a pushpad/touchpad device must be used and the actuating portion of the device must not extend more than half the width of the door. Crossbar style devices may not be used on balanced doors. The reason for this is that if the actuating portion extended all the way over to the hinge edge of the door, a building occupant could push on the wrong end of the panic device and the door would not open. In some jurisdictions, doors and hardware must meet testing requirements for hurricane and tornado protection. Consult the applicable codes and manufac- turers’ certifications for compliance information. The requirements for panic hardware vary by code. However, as more jurisdictions have adopted the International Building Code®, it has become less compli- cated to decide when and where to specify and supply panic hardware. The following codes were researched for this article. For more information, determine the code that is being enforced and refer to the appropriate edition of that code. International Building Code: 2003, 2006, 2009, 2012, 2015, 2018, 2021, 2024 NFPA 101: 2003, 2006, 2009, 2012, 2015, 2018, 2021, 2024 NFPA 70: 2002, 2005, 2008, 2011, 2014, 2017, 2020, 2023 For more information, please visit www.nfpa.org.