Allegion Fire, life safety and accessibility codes 37 Controlled access/free egress The majority of electrified hardware applications fall into this category. An access control reader is typically mounted on the ingress side of the opening, to control access. On the egress side, the door hardware allows free egress—just turn the lever or push the touchpad of the panic hardware. The access control reader does not inhibit egress, it controls access only, and the system typically includes an elec- trified lockset, electrified lever trim, electric strike, or electric latch retraction device. If electric latch retraction devices or electric strikes are installed on fire doors, they must automatically provide positive latching upon fire alarm activation. This type of system is not addressed by the codes as a special locking arrange- ment, because it allows free egress just as a standard mechanical lockset or panic hardware would. These doors are subject to the typical code requirements for operable hardware: doors must be readily openable from the egress side without keys, tools, or special knowledge or effort, and without tight grasping, tight pinch- ing, or twisting of the wrist. One releasing motion must unlatch the door from the egress side, and operable hardware must be mounted between 34–48 inches above the floor. A clarification was added to the 2024 I-Codes, in the section previously called “Monitored or Recorded Egress.” The section is now called “Monitored or Recorded Egress, and Access Control Systems.” To comply with this section, door openings must either be readily openable from the egress side without the use of a key or special knowledge or effort, or they must comply with one of the sections address- ing special locking arrangements. The vast majority of doors with access control systems are readily openable for egress as required by this section; applications that do not allow immediate free egress will typically fall into one of the categories outlined below and on the following pages. Delayed egress Delayed egress locking systems may include panic hardware or an electromagnetic lock with delayed egress circuitry, or a delayed egress controller used in combina- tion with other listed components. This hardware delays egress for 15 seconds (or 30 seconds when approved by the Authority Having Jurisdiction (AHJ)). The use of these locks is dependent upon the use group or occupancy classification, and the requirements vary between the IBC and NFPA 101. Prior to the 2018 edition, the IBC did not allow delayed egress locks on any assembly, educational, or high hazard occupancies. The 2018 and subsequent editions allow secondary courtroom Decoded: Electrified hardware refresher The International Building Code (IBC) Commentary and the NFPA 101 Handbook include information which helps to clarify the code requirements that pertain to electrified hardware. When a door equipped with an access control reader allows free egress using normal operation of the hardware, it is not considered one of the special locking arrangements. Although the code language has been refined over the last few editions of both the International Building Code (IBC) and NFPA 101 Life Safety Code, the code requirements for electrified hardware continue to be confusing for many, often resulting in inconsistent application and enforcement. There are seven basic code categories for electrified hardware used to control access or egress, and this edition of Decoded provides a brief refresher on each as well as some recent code changes. Many of these code applications, but not all, fall into the category commonly called “special locking arrangements.” Some jurisdictions have modified the national requirements for electrified hardware, so it’s very important to check local codes as well.