16 Allegion Fire, life safety and accessibility codes Locks, latches and alarm devices (7.2.1.5) Locks, if provided, shall not require the use of a key, tool or special knowledge or effort for operation from the egress side (does not apply to fire doors after exposure to elevated temperatures) Latch release devices ( 2024, 2021: 7.2.1.5.3; 2018, 2015, 2012: 7.2.1.5.10; 2009, 2006, 2003: 7.2.1.5.9) Latch or other fastening device on a door shall be provided with a releasing device having an obvious method of operation under all lighting conditions Releasing mechanism (except existing installations) shall be located between 34–48 inches (865–1220 mm) above the finished floor One single linear or rotational motion unlatches door (Refer to code for exceptions related to classrooms, dwelling units, and existing installations) On new installations, hardware must operate with one hand and without tight grasping, pinching, or twisting of the wrist Key-operated locks ( 2024, 2021: 7.2.1.5.6; 2018, 2015, 2012: 7.2.1.5.5; 2009, 2006, 2003: 7.2.1.5.4) Exterior doors and interior door assemblies to an individual tenant space or to a single tenant space may have key-operated locks from the egress side if: − Exception is permitted in the occupancy chapters for the specific occupancy − Signage provided on or adjacent to the door-refer to code for text and requirements − Lock is readily distinguishable as locked and door is unlocked when building is occupied − Key is immediately available to any occupant inside the building when door is locked − Provisions may be revoked by the AHJ (Authority Having Jurisdiction) for cause Stair enclosure re-entry ( 2024, 2021: 7.2.1.5.7; 2018, 2015, 2012: 7.2.1.5.8; 2009, 2006, 2003: 7.2.1.5.7) Doors in stair enclosures serving more than four stories shall meet one of the following criteria: − Re-entry from the stair enclosure to the interior of the building shall be provided (passage sets), or − An automatic release actuated by the fire alarm system shall unlock all stair enclosure doors to provide reentry (fail-safe locks or fail-safe FEH trim) − Locks must be listed to UL 294 or UL 1034 (2024 ed) − Selected re-entry: Selected doors may have locking hardware, provided that at least two levels are unlocked, there aren’t more than four stories between unlocked floors, and the top or next to the top floor is unlocked, signage on the stair side identifies unlocked doors, and signage on the stair side of locked doors indicates the location of the nearest unlocked door in each direction Note: Selected re-entry is included in NFPA 101, but not the IBC The following applications are not required to comply: − Existing installations in buildings that are not high-rise, as permitted by occupancy chapters − Stairs serving a building permitted to have a single exit, in accordance with the occupancy chapters − Existing installations in sprinklered high-rise buildings, as permitted in the occupancy chapters − Stairs in health care occupancies and detention/ correctional occupancies, where otherwise provided in the occupancy chapter Stair to roof ( 2024, 2021: 7.2.1.5.8; 2018, 2015, 2012: 7.2.1.5.9; 2009, 2006, 2003: 7.2.1.5.8) If stair enclosure allows access to the roof, door to the roof must be kept locked, preventing access to the roof, or must allow re-entry from the roof Highlights of NFPA 101®, Life Safety Code® 1 Note: In this code reference guide, “fire protection system” means an approved sprinkler system, approved fire alarm system or both. Numbers in brackets ( ) refer to applicable sections of the code publication. Refer to Classification of Occupancy section on page 6 for descriptions of occupancy types. 1 2024, 2021, 2018, 2015, 2012, 2009, 2006, and 2003 editions Copyright © 2023 NFPA
Fire Life Safety and Accessibility Codes Book
| Title Name |
Pages |
Delete |
Url |
| Empty |
Ai generated response may be inaccurate.
Search Text Block
Page #page_num
#doc_title
Hi $receivername|$receiveremail,
$sendername|$senderemail wrote these comments for you:
$message
$sendername|$senderemail would like for you to view the following digital edition.
Please click on the page below to be directed to the digital edition:
$thumbnail$pagenum
$link$pagenum
Your form submission was a success.
Downloading PDF
Generating your PDF, please wait...
This process might take longer please wait